


Certified Fire Door Installations
Safeguarding lives and buildings with BM Trada certified fire door installations
Fully Accredited for your peace of mind

Certified Fire Door Installations
Safeguarding lives and buildings with BM Trada certified fire door installations
Fully Accredited for your peace of mind

Certified Fire Door Installations
Safeguarding lives and buildings with BM Trada certified fire door installations
Fully Accredited for your peace of mind
BM Trada Certified Fire Door Installers
At TECS, we excel in professional fire door installations, delivering certified, compliant solutions that protect lives and properties nationwide. Specialising in commercial, residential, and public sector projects, our skilled team handles every detail—from precise fitting to seamless integration—ensuring minimal disruption and maximum safety.
BM Trada Certified Fire Door Installers
At TECS, we excel in professional fire door installations, delivering certified, compliant solutions that protect lives and properties nationwide. Specialising in commercial, residential, and public sector projects, our skilled team handles every detail—from precise fitting to seamless integration—ensuring minimal disruption and maximum safety.
BM Trada Certified Fire Door Installers
At TECS, we excel in professional fire door installations, delivering certified, compliant solutions that protect lives and properties nationwide. Specialising in commercial, residential, and public sector projects, our skilled team handles every detail—from precise fitting to seamless integration—ensuring minimal disruption and maximum safety.
Tailored Fire Door Installation Solutions
We provide expertly installed fire door packages, customized to your building and compliance needs:
FD30, FD60, FD120 fire-rated doors
Composite, timber, or steel doors
Fire-rated hardware (hinges, closers, latches)
Intumescent seals and smoke strips
Internal and external systems
Ensure safety and durability with our high-quality, compliant fire door solutions. Contact us to protect your property today.

Tailored Fire Door Installation Solutions
We provide expertly installed fire door packages, customized to your building and compliance needs:
FD30, FD60, FD120 fire-rated doors
Composite, timber, or steel doors
Fire-rated hardware (hinges, closers, latches)
Intumescent seals and smoke strips
Internal and external systems
Ensure safety and durability with our high-quality, compliant fire door solutions. Contact us to protect your property today.

Tailored Fire Door Installation Solutions
We provide expertly installed fire door packages, customized to your building and compliance needs:
FD30, FD60, FD120 fire-rated doors
Composite, timber, or steel doors
Fire-rated hardware (hinges, closers, latches)
Intumescent seals and smoke strips
Internal and external systems
Ensure safety and durability with our high-quality, compliant fire door solutions. Contact us to protect your property today.

Fire Doors Matter
Why Fire Doors are Important
Fire doors are essential for building safety, designed to resist fire and smoke for at least 30 minutes. Here's why they're crucial:
Key Facts:
Fire Doors Matter
Why Fire Doors are Important
Fire doors are essential for building safety, designed to resist fire and smoke for at least 30 minutes. Here's why they're crucial:
Key Facts:
Fire Doors Matter
Why Fire Doors are Important
Fire doors are essential for building safety, designed to resist fire and smoke for at least 30 minutes. Here's why they're crucial:
Key Facts:
#1 for Passive Fire Protection
Why Choose TECS for Fire Door Installations?
With highly skilled engineers and excellent back office support, you're in good hands
BM Trada Certified
BM TRADA Q-Mark certification, ensuring we deliver compliant solutions
Dedicated Helpdesk
We have a dedicated helpdesk to answer any queries
OneTrace Platform Technology
Audit-ready evidence with photographic proof and traceable records
QR Code Accessible Reports
Access previous work and surveys by scanning the QR code
Skilled Engineers
All work and surveys carried out by BM Trada trained engineers
Compliance Advice
Our advisors are on hand to advise you on passive fire compliance
#1 for Passive Fire Protection
Why Choose TECS for Fire Door Installations?
With highly skilled engineers and excellent back office support, you're in good hands
BM Trada Certified
BM TRADA Q-Mark certification, ensuring we deliver compliant solutions
Dedicated Helpdesk
We have a dedicated helpdesk to answer any queries
OneTrace Platform Technology
Audit-ready evidence with photographic proof and traceable records
QR Code Accessible Reports
Access previous work and surveys by scanning the QR code
Skilled Engineers
All work and surveys carried out by BM Trada trained engineers
Compliance Advice
Our advisors are on hand to advise you on passive fire compliance
#1 for Passive Fire Protection
Why Choose TECS for Fire Door Installations?
With highly skilled engineers and excellent back office support, you're in good hands
BM Trada Certified
BM TRADA Q-Mark certification, ensuring we deliver compliant solutions
Dedicated Helpdesk
We have a dedicated helpdesk to answer any queries
OneTrace Platform Technology
Audit-ready evidence with photographic proof and traceable records
QR Code Accessible Reports
Access previous work and surveys by scanning the QR code
Skilled Engineers
All work and surveys carried out by BM Trada trained engineers
Compliance Advice
Our advisors are on hand to advise you on passive fire compliance
Trusted by small and large companies
Trusted by small and large companies
Trusted by small and large companies
FAQ
Frequently Asked Questions
What is a fire door installation?
Fire door installation involves the proper fitting of fire-rated doors, frames, and associated hardware (e.g., hinges, seals, closers, and glazing) to ensure they provide effective fire resistance and smoke control. This process must follow precise guidelines to maintain the door's integrity during a fire. BM Trada offers Q-Mark certified installation schemes that verify compliance through trained professionals. Digital tools like OneTrace software can be used to document the installation process, including asset tagging with QR codes and real-time logging for traceability.
Why is a correct fire door installation important?
Correct installation is essential for fire doors to perform as intended, containing fire and smoke to allow safe evacuation and limit property damage. Poor installation, such as incorrect gaps or hardware, can lead to failure, resulting in loss of life or legal liabilities. In the UK, non-compliance can violate building regulations and lead to penalties. BM Trada's certification ensures high standards, providing assurance to building owners. Using software like OneTrace enhances accuracy by enabling digital workflows, compliance tracking, and audit-ready records, reducing errors in the installation phase.
What UK legislation governs fire door installation?
Key UK legislation and standards include: - **Building Regulations 2010 (Approved Document B)**: Requires fire doors in new builds and alterations to meet fire resistance standards (e.g., FD30 for 30 minutes), with proper installation to Approved Document B guidelines. - **BS 8214:2016**: Code of practice for fire door assemblies, covering installation methods, tolerances (e.g., 2-4mm gaps), and hardware compatibility. - **Fire Safety (England) Regulations 2022**: While focused on inspections, it indirectly impacts installation by requiring doors to be fit for purpose in high-rise residential buildings. - **Building Safety Act 2022**: Emphasizes accountability for fire safety in higher-risk buildings, mandating competent installation. - **2025 Updates (BS 9991:2024 and UKCA Marking)**: From June 2025, fire doors must be UKCA certified (replacing CE), tested to BS EN 1634-1 rather than BS 476-22. BS 9991:2024 updates fire safety for residential buildings, requiring sprinklers in new care homes and enhanced door standards. - **Regulatory Reform (Fire Safety) Order 2005**: Applies to non-domestic premises, requiring installations to support ongoing maintenance. Always engage certified experts like BM Trada to ensure adherence, especially with 2025 transitions to stricter testing and certification.
What is BM Trada's role in fire door installation?
BM Trada is a UKAS-accredited certification body that operates the Q-Mark Fire Door Installation Scheme, certifying installers to demonstrate competence in fitting fire doors compliant with BS 8214 and other standards. They provide training, audits, and third-party verification to ensure installations meet fire performance criteria. As part of Element Materials Technology, BM Trada also offers guidance on UKCA marking and 2025 updates. Certified companies often use digital tools like OneTrace, which integrates with BM Trada's frameworks for workflow management, real-time documentation, and compliance reporting during installation.
What are the requirements for fire door installation?
Fire door installation requirements vary by building type but generally include: - Use of certified components with matching fire ratings (e.g., FD30 or FD60) and UKCA marking from June 2025. - Adherence to BS 8214:2016 for fitting, including correct frame alignment, intumescent seals, and hardware installation. - Compliance with Approved Document B for locations like escape routes and compartments. - In high-risk buildings under the Building Safety Act 2022, installations must be by competent persons with documented evidence. - BM Trada recommends risk assessments and manufacturer instructions. Tools like OneTrace can help meet requirements by providing digital checklists, photo evidence, and automated compliance logs to ensure all steps are followed and auditable.
What does a BM Trada certified fire door installation involve?
A BM Trada certified installation typically includes: - Pre-installation surveys to assess site conditions and select compatible components. - Precise fitting of doors, frames, and hardware, ensuring gaps (2-4mm), seals, and closers function correctly. - Verification against standards like BS EN 1634-1 and BS 8214:2016. - Post-installation testing for operation and fire integrity. - Use of digital software such as OneTrace for asset tagging with QR codes, digital logging of each step, location mapping, compliance categorization, and generation of reports with photos and annotations in formats like PDF. - A final certification report with BM Trada approval, ensuring alignment with UK legislation like the 2025 UKCA requirements and Building Regulations. This process guarantees regulatory compliance and long-term performance through expert oversight and efficient tools.
FAQ
Frequently Asked Questions
What is a fire door installation?
Fire door installation involves the proper fitting of fire-rated doors, frames, and associated hardware (e.g., hinges, seals, closers, and glazing) to ensure they provide effective fire resistance and smoke control. This process must follow precise guidelines to maintain the door's integrity during a fire. BM Trada offers Q-Mark certified installation schemes that verify compliance through trained professionals. Digital tools like OneTrace software can be used to document the installation process, including asset tagging with QR codes and real-time logging for traceability.
Why is a correct fire door installation important?
Correct installation is essential for fire doors to perform as intended, containing fire and smoke to allow safe evacuation and limit property damage. Poor installation, such as incorrect gaps or hardware, can lead to failure, resulting in loss of life or legal liabilities. In the UK, non-compliance can violate building regulations and lead to penalties. BM Trada's certification ensures high standards, providing assurance to building owners. Using software like OneTrace enhances accuracy by enabling digital workflows, compliance tracking, and audit-ready records, reducing errors in the installation phase.
What UK legislation governs fire door installation?
Key UK legislation and standards include: - **Building Regulations 2010 (Approved Document B)**: Requires fire doors in new builds and alterations to meet fire resistance standards (e.g., FD30 for 30 minutes), with proper installation to Approved Document B guidelines. - **BS 8214:2016**: Code of practice for fire door assemblies, covering installation methods, tolerances (e.g., 2-4mm gaps), and hardware compatibility. - **Fire Safety (England) Regulations 2022**: While focused on inspections, it indirectly impacts installation by requiring doors to be fit for purpose in high-rise residential buildings. - **Building Safety Act 2022**: Emphasizes accountability for fire safety in higher-risk buildings, mandating competent installation. - **2025 Updates (BS 9991:2024 and UKCA Marking)**: From June 2025, fire doors must be UKCA certified (replacing CE), tested to BS EN 1634-1 rather than BS 476-22. BS 9991:2024 updates fire safety for residential buildings, requiring sprinklers in new care homes and enhanced door standards. - **Regulatory Reform (Fire Safety) Order 2005**: Applies to non-domestic premises, requiring installations to support ongoing maintenance. Always engage certified experts like BM Trada to ensure adherence, especially with 2025 transitions to stricter testing and certification.
What is BM Trada's role in fire door installation?
BM Trada is a UKAS-accredited certification body that operates the Q-Mark Fire Door Installation Scheme, certifying installers to demonstrate competence in fitting fire doors compliant with BS 8214 and other standards. They provide training, audits, and third-party verification to ensure installations meet fire performance criteria. As part of Element Materials Technology, BM Trada also offers guidance on UKCA marking and 2025 updates. Certified companies often use digital tools like OneTrace, which integrates with BM Trada's frameworks for workflow management, real-time documentation, and compliance reporting during installation.
What are the requirements for fire door installation?
Fire door installation requirements vary by building type but generally include: - Use of certified components with matching fire ratings (e.g., FD30 or FD60) and UKCA marking from June 2025. - Adherence to BS 8214:2016 for fitting, including correct frame alignment, intumescent seals, and hardware installation. - Compliance with Approved Document B for locations like escape routes and compartments. - In high-risk buildings under the Building Safety Act 2022, installations must be by competent persons with documented evidence. - BM Trada recommends risk assessments and manufacturer instructions. Tools like OneTrace can help meet requirements by providing digital checklists, photo evidence, and automated compliance logs to ensure all steps are followed and auditable.
What does a BM Trada certified fire door installation involve?
A BM Trada certified installation typically includes: - Pre-installation surveys to assess site conditions and select compatible components. - Precise fitting of doors, frames, and hardware, ensuring gaps (2-4mm), seals, and closers function correctly. - Verification against standards like BS EN 1634-1 and BS 8214:2016. - Post-installation testing for operation and fire integrity. - Use of digital software such as OneTrace for asset tagging with QR codes, digital logging of each step, location mapping, compliance categorization, and generation of reports with photos and annotations in formats like PDF. - A final certification report with BM Trada approval, ensuring alignment with UK legislation like the 2025 UKCA requirements and Building Regulations. This process guarantees regulatory compliance and long-term performance through expert oversight and efficient tools.
FAQ
Frequently Asked Questions
What is a fire door installation?
Fire door installation involves the proper fitting of fire-rated doors, frames, and associated hardware (e.g., hinges, seals, closers, and glazing) to ensure they provide effective fire resistance and smoke control. This process must follow precise guidelines to maintain the door's integrity during a fire. BM Trada offers Q-Mark certified installation schemes that verify compliance through trained professionals. Digital tools like OneTrace software can be used to document the installation process, including asset tagging with QR codes and real-time logging for traceability.
Why is a correct fire door installation important?
Correct installation is essential for fire doors to perform as intended, containing fire and smoke to allow safe evacuation and limit property damage. Poor installation, such as incorrect gaps or hardware, can lead to failure, resulting in loss of life or legal liabilities. In the UK, non-compliance can violate building regulations and lead to penalties. BM Trada's certification ensures high standards, providing assurance to building owners. Using software like OneTrace enhances accuracy by enabling digital workflows, compliance tracking, and audit-ready records, reducing errors in the installation phase.
What UK legislation governs fire door installation?
Key UK legislation and standards include: - **Building Regulations 2010 (Approved Document B)**: Requires fire doors in new builds and alterations to meet fire resistance standards (e.g., FD30 for 30 minutes), with proper installation to Approved Document B guidelines. - **BS 8214:2016**: Code of practice for fire door assemblies, covering installation methods, tolerances (e.g., 2-4mm gaps), and hardware compatibility. - **Fire Safety (England) Regulations 2022**: While focused on inspections, it indirectly impacts installation by requiring doors to be fit for purpose in high-rise residential buildings. - **Building Safety Act 2022**: Emphasizes accountability for fire safety in higher-risk buildings, mandating competent installation. - **2025 Updates (BS 9991:2024 and UKCA Marking)**: From June 2025, fire doors must be UKCA certified (replacing CE), tested to BS EN 1634-1 rather than BS 476-22. BS 9991:2024 updates fire safety for residential buildings, requiring sprinklers in new care homes and enhanced door standards. - **Regulatory Reform (Fire Safety) Order 2005**: Applies to non-domestic premises, requiring installations to support ongoing maintenance. Always engage certified experts like BM Trada to ensure adherence, especially with 2025 transitions to stricter testing and certification.
What is BM Trada's role in fire door installation?
BM Trada is a UKAS-accredited certification body that operates the Q-Mark Fire Door Installation Scheme, certifying installers to demonstrate competence in fitting fire doors compliant with BS 8214 and other standards. They provide training, audits, and third-party verification to ensure installations meet fire performance criteria. As part of Element Materials Technology, BM Trada also offers guidance on UKCA marking and 2025 updates. Certified companies often use digital tools like OneTrace, which integrates with BM Trada's frameworks for workflow management, real-time documentation, and compliance reporting during installation.
What are the requirements for fire door installation?
Fire door installation requirements vary by building type but generally include: - Use of certified components with matching fire ratings (e.g., FD30 or FD60) and UKCA marking from June 2025. - Adherence to BS 8214:2016 for fitting, including correct frame alignment, intumescent seals, and hardware installation. - Compliance with Approved Document B for locations like escape routes and compartments. - In high-risk buildings under the Building Safety Act 2022, installations must be by competent persons with documented evidence. - BM Trada recommends risk assessments and manufacturer instructions. Tools like OneTrace can help meet requirements by providing digital checklists, photo evidence, and automated compliance logs to ensure all steps are followed and auditable.
What does a BM Trada certified fire door installation involve?
A BM Trada certified installation typically includes: - Pre-installation surveys to assess site conditions and select compatible components. - Precise fitting of doors, frames, and hardware, ensuring gaps (2-4mm), seals, and closers function correctly. - Verification against standards like BS EN 1634-1 and BS 8214:2016. - Post-installation testing for operation and fire integrity. - Use of digital software such as OneTrace for asset tagging with QR codes, digital logging of each step, location mapping, compliance categorization, and generation of reports with photos and annotations in formats like PDF. - A final certification report with BM Trada approval, ensuring alignment with UK legislation like the 2025 UKCA requirements and Building Regulations. This process guarantees regulatory compliance and long-term performance through expert oversight and efficient tools.
Ready to discuss your Fire Door Installation needs?
Our team of highly knowledgable experts are ready to help
Ready to discuss your Fire Door Installation needs?
Our team of highly knowledgable experts are ready to help
Ready to discuss your Fire Door Installation needs?
Our team of highly knowledgable experts are ready to help





















